Intruder Alarms
Intruder alarm systems generally fall into five categories and for insurance purposes fall into four different grades.
Grade 1 - Audible Only: A stand alone system that is intended to deter would be intruders and alert the attention of others in the local vicinity via the use of internal and external sounders.
If required a basic telephone communicator (speech dialer) can be connected to an audible alarm enabling the system to contact you in the event of alarm activation via voice or text. This is a low cost solution with no annual monitoring charges.
Grade 2 - Digital Communicator: Incorporating the above with the addition of a direct communication to an alarm receiving centre (ARC) via the connection of an analogue telephone line. In the event of alarm activation a signal will be sent to the ARC where an operator will determine which level of response is required. Police, Fire Brigade, Key-holder’s etc
Grade 2 & 3 - RedCare Communicator: Incorporating all the above with the addition of a 24 Hour monitored telephone line. If the telephone line is disconnected or tampered with immediate police response would occur if the alarm is set.
RedCare GSM and DualCom Communicators: Incorporating all the above with the addition of a secondary communication path via the mobile phone networks. If the telephone line is disconnected or tampered with then the alarm can still communicate via the mobile network, if the mobile network is down then immediate police response would occur if the alarm is set.
Grade 3 & 4 - All of our security systems can be integrated with ancillary equipment such as CCTV, Fire Alarms and Access Control. This could provide an all in one solution; Minimizing the complexity of user operation and reducing initial cost.
All the systems that we design, install and commission include preventative maintenance giving you peace of mind that a 24 hour service is always available if required.

We are an NSI accredited installer, which means we are regulated to the highest standard.
All installations comply with the new European Standards PD6662. (PD6662 is the UK implementation of the European Standard EN50131 and has superseded the British standard BS 4737).
In addition to the above we comply with the requirements of the Association of Chief Police Officers (ACPO) policy that deals with police response and false alarm management.
Visit the NSI website for more information - www.nsi.org.uk

- Design
- Installation
- Maintenance Contracts
- System Takeovers
- Upgrades
- Repairs
- 24 Hour Call Out